Templates

Contents Hide

 

 

 

Use filename generator

This option uses settings from Plant Design Administrator.

 

Use PlotFile Path

Use Plot File Path allows users to use Isogen© dynamic file naming.

Dynamic file naming is a method of naming files output by Isogen© using dynamic attribute values. This applies to all output files, such as the drawings and reports. Both drawings and reports file names can be set in I-Configure, but additionally Plot File Path (which defines both folder and file name) for drawings can be set in Isometric. This method can also be used to create folders.

 

Isometric directory

It is the location where isometrics projects should be stored to be applicable as templates for creating isometric drawings.

To select such a directory properly the ProjectList.xml file (stored inside) should be selected (via browse dialog).

Particular Project and Drawing styles can be then selected below.

 

Allow Isometric to Write to Isogen Styles

Allows to change/adapt existing dynamic file naming definitions settings that are in both Isometric and I-Configure, such as units and drawing file name. Checking causes a new button next to each existing drawing style to appear.

Opens an Isometric Output File Name Editor dialog with the corresponding path.

 

 

Isometric Output File Name Editor contains all available macros (variables). Macros define a syntax for drawing file names based on the new Isogen© Dynamic File Naming method.

Each macro can be combined individually or together with others to a desired file name syntax. It is possible to use strings and/or allowed characters.

 

If the value of a style is Error then there is a mismatch in Isometric and an I-Configure settings of a style, select the word Error to learn more about the issue. To fix the error, just check Allow Isometric to Write to Isogen Styles, select the word Error and the I-Configure settings is changed automatically to match the Isometric settings or fix the mismatch manually in I-Configure.

 

If the value of a style is OK, then the settings in Isometric matches settings of the corresponding Isogen style, visible in I-Configure under Plot File Path property.

The definitions are then used for file names of the drawings that will be generated with this style in the future. It does not overwrite old drawings that were generated before this Plot File Path definition was made.

 

File names for reports can also be based on Isogen © Dynamic File Naming, this can be set in the I-Configure tool for the respective style and its reports.

When generating drawings from a 3d pipeline with more than one style at once, where assembly name is used for drawing filename, there must be an additional fixed differentiator in the plot file path definition for the styles. Otherwise, only one drawing is generated in the output folder, which is overwritten several times.

 

Keep PCF file in output folder

This box determines whether the PCF files (created by Smap3D Isometric as input for Personal ISOGEN©) should be deleted (default) or kept in the output path.

 

Copy IDF files to output folder

Checking this box enables to copy IDF files (generated through the Personal ISOGEN© run) to the output path.

 

Convert to CAD

Checking this box allows, if a proper CAD drawing template is selected, to export automatically the resulting isometric drawings (created in DWG format) to the CAD native drawing format.

To get correct results, the units in the isometric drawings (DWG) and selected CAD drawing template must match.

 

Isometrics background color

Sets the background color of the isometric drawing previews displayed in Step 4.

 

Attempt to generate single drawing

If checked, Smap3D Isometric will try to create just one drawing containing all the pipelines.

It is only possible in the case that those pipelines (pipeline paths) are connected together and are not too complex.

 

If they are not, several drawings will be created.

This fact will be also mentioned in the output log (available in Step 4).

If the box is not checked a separate drawing will be created for every single pipeline.