This function allows to change the pipe length. The single straight pipe which is based on one 3D Sketch line has to be selected. When this function runs it displays dialogue with two options.
If this option is selected the Remove function sets length of the 3D Sketch line to the value which causes that the selected Pipe has zero length.
Pipe is deleted and a pipeline path is updated.
If this option is selected then value for a new pipe length is enabled. The current pipe length is pre-filled. It is allowed to change the new length value.
Adapt pipe sets length of the 3D Sketch line to the value which causes that the selected Pipe has set length. Pipe is updated as well as the pipeline path.
If the pipeline has no degree of freedom, then it's not possible to remove or adapt the pipe length.